const ( COTPTypeCR = 0xE0 // Connection Request (type code 14 = 0xE in upper nibble) COTPTypeCC = 0xD0 // Connection Confirm (type code 13 = 0xD in upper nibble) COTPTypeDR = 0x80 // Disconnect Request (type code 8 = 0x8 in upper nibble) COTPTypeDC = 0xC0 // Disconnect Confirm (type code 12 = 0xC in upper nibble) COTPTypeDT = 0xF0 // Data Transfer (type code 15 = 0xF in upper nibble) COTPTypeED = 0x10 // Expedited Data (type code 1 = 0x1 in upper nibble) COTPTypeAK = 0x60 // Data Acknowledgement (type code 6 = 0x6 in upper nibble) COTPTypeEA = 0x20 // Expedited Data Acknowledgement (type code 2 = 0x2 in upper nibble) COTPTypeRJ = 0x50 // Reject (type code 5 = 0x5 in upper nibble) COTPTypeER = 0x70 // TPDU Error (type code 7 = 0x7 in upper nibble) )
COTP PDU Types (ISO 8073) These are the upper nibble values after masking with 0xF0 The PDU type is encoded in the upper nibble of the COTP header byte
const ( S7CommMsgTypeJobRequest = 0x01 // Job Request (client -> PLC) S7CommMsgTypeAck = 0x02 // Acknowledgement without data S7CommMsgTypeAckData = 0x03 // Acknowledgement with data S7CommMsgTypeUserData = 0x07 // UserData (e.g., block upload, CPU info) )
S7comm Message Types (ROSCTR - Remote Operating Service Control)
const ( S7FuncCPUServices = 0x00 // CPU services S7FuncSetupCommunication = 0xF0 // Setup communication S7FuncReadVar = 0x04 // Read variable S7FuncWriteVar = 0x05 // Write variable S7FuncRequestDownload = 0x1A // Request download S7FuncDownloadBlock = 0x1B // Download block S7FuncDownloadEnded = 0x1C // Download ended S7FuncStartUpload = 0x1D // Start upload S7FuncUpload = 0x1E // Upload S7FuncEndUpload = 0x1F // End upload S7FuncPIService = 0x28 // PI (Program Invocation) service S7FuncPLCStop = 0x29 // PLC stop S7FuncPLCControl = 0x00 // PLC control (same as CPU services) )
S7comm Function Codes
const ( S7SyntaxIDS7Any = 0x10 // S7-Any pointer (classic addressing) S7SyntaxIDDriveESAny = 0x11 // Drive ES Any S7SyntaxID1200Sym = 0x12 // 1200 symbolic addressing S7SyntaxIDDBRead = 0x13 // DB read (PBC ID) S7SyntaxIDNCK = 0x82 // NCK addressing (Sinumerik) S7SyntaxIDDriveMCSync = 0xA2 // Drive motion control sync )
S7comm Syntax IDs
const ( S7AreaSysInfo = 0x03 // System info of 200 family S7AreaSysFlags = 0x05 // System flags of 200 family S7AreaAnalogInputs = 0x06 // Analog inputs of 200 family S7AreaAnalogOutputs = 0x07 // Analog outputs of 200 family S7AreaCounter = 0x1C // Counter (200 family) / (S7-300/400) S7AreaTimer = 0x1D // Timer (200 family) / (S7-300/400) S7AreaCounter200 = 0x1E // Counter (200 family IEC) S7AreaTimer200 = 0x1F // Timer (200 family IEC) S7AreaPeripheral = 0x80 // Direct peripheral access (P) - critical for I/O S7AreaInputs = 0x81 // Process inputs (I) S7AreaOutputs = 0x82 // Process outputs (Q) S7AreaFlags = 0x83 // Bit memory/Merker (M) S7AreaDB = 0x84 // Data blocks (DB) S7AreaDI = 0x85 // Instance data blocks (DI) S7AreaLocal = 0x86 // Local data (L) S7AreaVMemory = 0x87 // V-Memory (200 family) )
S7comm Memory Areas (from Wireshark packet-s7comm.c)
const ( S7TransportSizeNull = 0x00 // NULL S7TransportSizeBit = 0x01 // BIT S7TransportSizeByte = 0x02 // BYTE/CHAR S7TransportSizeChar = 0x03 // CHAR S7TransportSizeWord = 0x04 // WORD S7TransportSizeInt = 0x05 // INT S7TransportSizeDWord = 0x06 // DWORD S7TransportSizeDInt = 0x07 // DINT S7TransportSizeReal = 0x08 // REAL S7TransportSizeDate = 0x09 // DATE S7TransportSizeTOD = 0x0A // TOD (Time of Day) S7TransportSizeTime = 0x0B // TIME S7TransportSizeS5Time = 0x0C // S5TIME S7TransportSizeDT = 0x0F // DATE_AND_TIME S7TransportSizeCounter = 0x1C // COUNTER S7TransportSizeTimer = 0x1D // TIMER S7TransportSizeIECCounter = 0x1E // IEC COUNTER (200 family) S7TransportSizeIECTimer = 0x1F // IEC TIMER (200 family) S7TransportSizeHSCounter = 0x20 // HS COUNTER (200 family) )
S7comm Transport Sizes (in request)
const ( S7ReturnCodeReserved = 0x00 // Reserved S7ReturnCodeHardwareError = 0x01 // Hardware error S7ReturnCodeAccessingObject = 0x03 // Accessing the object not allowed S7ReturnCodeAddressOutOfRange = 0x05 // Address out of range S7ReturnCodeDataTypeNotSupported = 0x06 // Data type not supported S7ReturnCodeDataTypeInconsistent = 0x07 // Data type inconsistent S7ReturnCodeObjectNotExists = 0x0A // Object does not exist S7ReturnCodeSuccess = 0xFF // Success )
S7comm Return Codes
const ( S7UserDataFGProgram = 0x01 // Programmer commands S7UserDataFGCyclic = 0x02 // Cyclic data S7UserDataFGBlock = 0x03 // Block functions S7UserDataFGCPUFunc = 0x04 // CPU functions S7UserDataFGSecurity = 0x05 // Security S7UserDataFGPBCBSend = 0x06 // PBC BSEND/BRECV S7UserDataFGTime = 0x07 // Time functions S7UserDataFGNCProgram = 0x0F // NC Programming (Sinumerik) )
UserData function groups (from Wireshark packet-s7comm.h)
const ( S7UserDataCPUReadSZL = 0x01 // Read SZL (System Status List) S7UserDataCPUMsgService = 0x02 // Message service S7UserDataCPUDiagMessage = 0x03 // Diagnostic message S7UserDataCPUAlarmQuery = 0x13 // Alarm query )
UserData subfunctions for CPU Functions (0x04)
const ( S7UserDataTimeRead = 0x01 // Read clock S7UserDataTimeSet = 0x02 // Set clock S7UserDataTimeReadF = 0x03 // Read clock (F) S7UserDataTimeSet2 = 0x04 // Set clock )
UserData subfunctions for Time Functions (0x07)
const ( S7UserDataCyclicMem = 0x01 // Memory S7UserDataCyclicUnsubscr = 0x04 // Unsubscribe )
UserData subfunctions for Cyclic Data (0x02)
const ( S7PIServicePProgram = "_INSE" // Insert program S7PIServiceModu = "_MODU" // Module S7PIServiceGarb = "_GARB" // Garbage collection S7PIServiceNStop = "P_PROGRAM" // Stop program )
PI Service names (Program Invocation)
const ( SZLIDModuleID = 0x0011 // Module identification SZLIDCPUCharacter = 0x0012 // CPU characteristics SZLIDMemoryAreas = 0x0013 // Memory areas SZLIDSystemAreas = 0x0014 // System areas SZLIDBlockTypes = 0x0015 // Block types SZLIDCPUType = 0x001C // CPU type SZLIDComponentID = 0x001D // Component identification SZLIDInterruptStatus = 0x0022 // Interrupt status SZLIDAssignmentList = 0x0025 // Assignment list SZLIDCPUStatus = 0x0074 // CPU status SZLIDModeTransition = 0x0090 // Mode transition SZLIDStartupInfo = 0x0094 // Startup information SZLIDCommunication = 0x0111 // Communication status SZLIDLEDStatus = 0x0019 // LED status SZLIDRackStation = 0x0091 // Rack/station status SZLIDDiagBuffer = 0x00A0 // Diagnostic buffer )
SZL ID classes (System Status List - from packet-s7comm_szl_ids.h)
const ( S7BlockTypeOB = 0x08 // Organization Block S7BlockTypeDB = 0x0A // Data Block S7BlockTypeSDB = 0x0B // System Data Block S7BlockTypeFC = 0x0C // Function S7BlockTypeSFC = 0x0D // System Function S7BlockTypeFB = 0x0E // Function Block S7BlockTypeSFB = 0x0F // System Function Block )
Block types for block services
const ( S7AlarmTypeScan = 0x01 // Scan alarm S7AlarmTypeAlarm8 = 0x02 // Alarm_8 S7AlarmTypeAlarm8P = 0x04 // Alarm_8P S7AlarmTypeNotify = 0x05 // Notify S7AlarmTypeAlarmS = 0x06 // Alarm_S (SQ) S7AlarmTypeAlarmSQ = 0x07 // Alarm_SQ S7AlarmTypeAlarm = 0x08 // Alarm S7AlarmTypeAlarmAck = 0x09 // Alarm Ack S7AlarmTypeAlarmLock = 0x0A // Alarm Lock )
Alarm types
const (
S7VarSpecTypeItem = 0x12 // Item specification
)
S7comm Variable Specification Types
Variables ¶
var Decoder = &decoder.StreamDecoder{ Type: types.Type_NC_S7Comm, Name: serviceS7Comm, Description: "Siemens S7 Communication Protocol for ICS/SCADA PLC communication", PostInit: func(d *decoder.StreamDecoder) error { var err error s7commLog, _, err = logging.InitZapLogger( decoderconfig.Instance.Out, "s7comm", decoderconfig.Instance.Debug, ) return err }, CanDecode: func(client, server []byte) bool { return canDecodeS7Comm(client) || canDecodeS7Comm(server) }, DeInit: func(sd *decoder.StreamDecoder) error { return s7commLog.Sync() }, Factory: &s7commReader{}, Typ: core.TCP, }
Decoder for protocol analysis and writing audit records to disk.
Functions ¶
This section is empty.
Types ¶
This section is empty.