The first number is the count of modules that contain a package that imports this one. The module count is a better indicator of popularity than the package count. A module with 100 importing packages is counted only once instead of 100 times, reflecting the fact that the choice to use the package was likely made only once, not 100 times.
A '?' means that the value hasn't been computed yet.

README

Modbus Input Plugin

The Modbus plugin collects Discrete Inputs, Coils, Input Registers and Holding Registers via Modbus TCP or Modbus RTU/ASCII.

Configuration
[[inputs.modbus]]
  ## Connection Configuration
  ##
  ## The module supports connections to PLCs via MODBUS/TCP or
  ## via serial line communication in binary (RTU) or readable (ASCII) encoding
  ##
  ## Device name
  name = "Device"

  ## Slave ID - addresses a MODBUS device on the bus
  ## Range: 0 - 255 [0 = broadcast; 248 - 255 = reserved]
  slave_id = 1

  ## Timeout for each request
  timeout = "1s"

  ## Maximum number of retries and the time to wait between retries
  ## when a slave-device is busy.
  # busy_retries = 0
  # busy_retries_wait = "100ms"

  # TCP - connect via Modbus/TCP
  controller = "tcp://localhost:502"

  ## Serial (RS485; RS232)
  # controller = "file:///dev/ttyUSB0"
  # baud_rate = 9600
  # data_bits = 8
  # parity = "N"
  # stop_bits = 1
  # transmission_mode = "RTU"


  ## Measurements
  ##

  ## Digital Variables, Discrete Inputs and Coils
  ## name    - the variable name
  ## address - variable address

  discrete_inputs = [
    { name = "Start",          address = [0]},
    { name = "Stop",           address = [1]},
    { name = "Reset",          address = [2]},
    { name = "EmergencyStop",  address = [3]},
  ]
  coils = [
    { name = "Motor1-Run",     address = [0]},
    { name = "Motor1-Jog",     address = [1]},
    { name = "Motor1-Stop",    address = [2]},
  ]

  ## Analog Variables, Input Registers and Holding Registers
  ## measurement - the (optional) measurement name, defaults to "modbus"
  ## name       - the variable name
  ## byte_order - the ordering of bytes
  ##  |---AB, ABCD   - Big Endian
  ##  |---BA, DCBA   - Little Endian
  ##  |---BADC       - Mid-Big Endian
  ##  |---CDAB       - Mid-Little Endian
  ## data_type  - INT16, UINT16, INT32, UINT32, INT64, UINT64, FLOAT32, FLOAT32-IEEE (the IEEE 754 binary representation)
  ## scale      - the final numeric variable representation
  ## address    - variable address

  holding_registers = [
    { name = "PowerFactor", byte_order = "AB",   data_type = "FLOAT32", scale=0.01,  address = [8]},
    { name = "Voltage",     byte_order = "AB",   data_type = "FLOAT32", scale=0.1,   address = [0]},
    { name = "Energy",      byte_order = "ABCD", data_type = "FLOAT32", scale=0.001, address = [5,6]},
    { name = "Current",     byte_order = "ABCD", data_type = "FLOAT32", scale=0.001, address = [1,2]},
    { name = "Frequency",   byte_order = "AB",   data_type = "FLOAT32", scale=0.1,   address = [7]},
    { name = "Power",       byte_order = "ABCD", data_type = "FLOAT32", scale=0.1,   address = [3,4]},
  ]
  input_registers = [
    { name = "TankLevel",   byte_order = "AB",   data_type = "INT16",   scale=1.0,     address = [0]},
    { name = "TankPH",      byte_order = "AB",   data_type = "INT16",   scale=1.0,     address = [1]},
    { name = "Pump1-Speed", byte_order = "ABCD", data_type = "INT32",   scale=1.0,     address = [3,4]},
  ]
Metrics

Metric are custom and configured using the discrete_inputs, coils, holding_register and input_registers options.

Example Output
$ ./telegraf -config telegraf.conf -input-filter modbus -test
modbus.InputRegisters,host=orangepizero Current=0,Energy=0,Frecuency=60,Power=0,PowerFactor=0,Voltage=123.9000015258789 1554079521000000000

Documentation

Index

Constants

This section is empty.

Variables

This section is empty.

Functions

This section is empty.

Types

type Modbus

type Modbus struct {
	Name             string            `toml:"name"`
	Controller       string            `toml:"controller"`
	TransmissionMode string            `toml:"transmission_mode"`
	BaudRate         int               `toml:"baud_rate"`
	DataBits         int               `toml:"data_bits"`
	Parity           string            `toml:"parity"`
	StopBits         int               `toml:"stop_bits"`
	SlaveID          int               `toml:"slave_id"`
	Timeout          internal.Duration `toml:"timeout"`
	Retries          int               `toml:"busy_retries"`
	RetriesWaitTime  internal.Duration `toml:"busy_retries_wait"`
	DiscreteInputs   []fieldContainer  `toml:"discrete_inputs"`
	Coils            []fieldContainer  `toml:"coils"`
	HoldingRegisters []fieldContainer  `toml:"holding_registers"`
	InputRegisters   []fieldContainer  `toml:"input_registers"`
	// contains filtered or unexported fields
}

Modbus holds all data relevant to the plugin

func (*Modbus) Description

func (m *Modbus) Description() string

Description returns a short description of what the plugin does

func (*Modbus) Gather

func (m *Modbus) Gather(acc telegraf.Accumulator) error

Gather implements the telegraf plugin interface method for data accumulation

func (*Modbus) Init

func (m *Modbus) Init() error

func (*Modbus) InitRegister

func (m *Modbus) InitRegister(fields []fieldContainer, name string) error

func (*Modbus) SampleConfig

func (m *Modbus) SampleConfig() string

SampleConfig returns a basic configuration for the plugin