The first number is the count of modules that contain a package that imports this one. The module count is a better indicator of popularity than the package count. A module with 100 importing packages is counted only once instead of 100 times, reflecting the fact that the choice to use the package was likely made only once, not 100 times.
A '?' means that the value hasn't been computed yet.

README

APCUPSD Input Plugin

This plugin reads data from an apcupsd daemon over its NIS network protocol.

Requirements

apcupsd should be installed and it's daemon should be running.

Global configuration options

In addition to the plugin-specific configuration settings, plugins support additional global and plugin configuration settings. These settings are used to modify metrics, tags, and field or create aliases and configure ordering, etc. See the CONFIGURATION.md for more details.

Configuration

# Monitor APC UPSes connected to apcupsd
[[inputs.apcupsd]]
  # A list of running apcupsd server to connect to.
  # If not provided will default to tcp://127.0.0.1:3551
  servers = ["tcp://127.0.0.1:3551"]

  ## Timeout for dialing server.
  timeout = "5s"

Metrics

  • apcupsd
    • tags:
      • serial
      • ups_name
      • status (string representing the set status_flags)
      • model
    • fields:
      • status_flags (status-bits)
      • input_voltage
      • load_percent
      • battery_charge_percent
      • time_left_ns
      • output_voltage
      • internal_temp
      • battery_voltage
      • input_frequency
      • time_on_battery_ns
      • cumulative_time_on_battery_ns
      • nominal_input_voltage
      • nominal_battery_voltage
      • nominal_power
      • firmware
      • battery_date
      • last_transfer
      • number_transfers

Example Output

apcupsd,serial=AS1231515,status=ONLINE,ups_name=name1 time_on_battery=0,load_percent=9.7,time_left_minutes=98,output_voltage=230.4,internal_temp=32.4,battery_voltage=27.4,input_frequency=50.2,input_voltage=230.4,battery_charge_percent=100,status_flags=8i 1490035922000000000

Documentation

Index

Constants

This section is empty.

Variables

This section is empty.

Functions

This section is empty.

Types

type ApcUpsd

type ApcUpsd struct {
	Servers []string
	Timeout config.Duration
}

func (*ApcUpsd) Gather

func (h *ApcUpsd) Gather(acc telegraf.Accumulator) error

func (*ApcUpsd) SampleConfig

func (*ApcUpsd) SampleConfig() string