Documentation
¶
Index ¶
- func AllDeviceNames() []string
- func DeyeRegisters() *modbus.RegisterSet
- func FroniusMeterRegisters() *modbus.RegisterSet
- func FroniusRegisters() *modbus.RegisterSet
- func GetRegisterSet(name string) *modbus.RegisterSet
- func HuaweiRegisters() *modbus.RegisterSet
- func PixiiRegisters() *modbus.RegisterSet
- func SDM630Registers() *modbus.RegisterSet
- func SMARegisters() *modbus.RegisterSet
- func SolarEdgeRegisters() *modbus.RegisterSet
- func SolisRegisters() *modbus.RegisterSet
- func SungrowRegisters() *modbus.RegisterSet
Constants ¶
This section is empty.
Variables ¶
This section is empty.
Functions ¶
func AllDeviceNames ¶
func AllDeviceNames() []string
AllDeviceNames returns all registered device names (one per device, canonical name).
func DeyeRegisters ¶
func DeyeRegisters() *modbus.RegisterSet
DeyeRegisters returns the RegisterSet for Deye hybrid inverters. Addresses from firmware profile: deye Deye uses Holding Registers (FC 0x03). Notable: Deye uses low register addresses (0-700 range).
func FroniusMeterRegisters ¶
func FroniusMeterRegisters() *modbus.RegisterSet
FroniusMeterRegisters returns the RegisterSet for Fronius Smart Meter (TS 65A-3). Addresses from firmware profile: fronius_smart_meter SunSpec Meter model, Holding Registers (FC 0x03). The gateway reads with base address 40073, actual Modbus addresses are offset+1.
func FroniusRegisters ¶
func FroniusRegisters() *modbus.RegisterSet
FroniusRegisters returns the RegisterSet for Fronius GEN24 Plus inverters. Addresses from firmware profile: fronius (SunSpec-based) Fronius uses Holding Registers (FC 0x03) with SunSpec model layout. Note: Fronius firmware uses base address 40069 for SunSpec inverter model.
func GetRegisterSet ¶
func GetRegisterSet(name string) *modbus.RegisterSet
GetRegisterSet returns the RegisterSet for a given profile/device name. Returns nil if no register set is defined for the name.
func HuaweiRegisters ¶
func HuaweiRegisters() *modbus.RegisterSet
HuaweiRegisters returns the RegisterSet for Huawei SUN2000 hybrid inverters. Addresses from firmware profile: huawei Huawei uses Holding Registers (FC 0x03) for most reads.
func PixiiRegisters ¶
func PixiiRegisters() *modbus.RegisterSet
PixiiRegisters returns the RegisterSet for Pixii PowerShaper 2 (battery-only). Addresses from firmware profile: pixii Pixii uses SunSpec models over Holding Registers (FC 0x03). Note: Pixii is battery-only, no PV. Uses SunSpec Storage + Meter models.
func SDM630Registers ¶
func SDM630Registers() *modbus.RegisterSet
SDM630Registers returns the RegisterSet for Eastron SDM630 energy meters. All registers use F32 (IEEE 754 float), Big Endian, Input Registers (FC 0x04).
func SMARegisters ¶
func SMARegisters() *modbus.RegisterSet
SMARegisters returns the RegisterSet for SMA Sunny Tripower inverters. Addresses from firmware profile: sma SMA uses Holding Registers (FC 0x03) with SMA-specific register map. SMA uses U32 for most values, U64 for energy counters.
func SolarEdgeRegisters ¶
func SolarEdgeRegisters() *modbus.RegisterSet
SolarEdgeRegisters returns the RegisterSet for SolarEdge inverters with StorEdge. Addresses from firmware profile: solaredge SolarEdge uses SunSpec models over Holding Registers (FC 0x03). Note: SolarEdge uses scale factor (SF) registers adjacent to value registers.
func SolisRegisters ¶
func SolisRegisters() *modbus.RegisterSet
SolisRegisters returns the RegisterSet for Solis Hybrid inverters. Addresses from firmware profile: solis Solis uses Input Registers (FC 0x04) for reads, Holding (FC 0x03) for control.
func SungrowRegisters ¶
func SungrowRegisters() *modbus.RegisterSet
SungrowRegisters returns the RegisterSet for Sungrow SH Hybrid inverters. Register addresses are 0-based (firmware addresses).
Types ¶
This section is empty.