examples/hmi — end-to-end 组态 / HMI on scada.Services

A minimal, runnable HMI that exercises the entire Silk SCADA runtime loop — from a simulated field device all the way to live widgets, alarms, a trend chart and a statistics table — with no hand-written per-widget binding code. It mirrors what the ged code generator now emits: build a form of tag-named widgets and backend-free panels, then hand the whole tree to scada.BindScreen.

What it proves

sim.Sim (sine waveforms)
  -> driver.Poller               reads every 500ms
      -> services.Tags           core.TagDB — the one real-time point registry
          ├─ AlarmDB.Watch       -> alarm bridge -> event log + notify + AlarmPanel
          ├─ Historian.Record    -> SQLite sample store (TrendPanel range replay)
          ├─ Stats.Collector     -> StatsPanel (count / min / max / avg / last)
          └─ BindScreen tag bind:
                 Tank.SetTagName("level")           -> BindTagAnimated -> fill eases
                 DigitalDisplay.SetTagName("temp")  -> BindTagAnimated -> readout eases
              TrendPanel (TrendTag "temp")          -> owned LineChart scrolls live

The whole chain — sim → Poller → services.Tags → BindScreen → widgets / AlarmPanel / TrendPanel / StatsPanel + alarms + historian — runs from ~40 lines of main, and main.go contains zero gui.BindTag calls of its own.

The four wiring calls

Call What it installs
scada.New(cfg) The runtime container: one TagDB, AlarmDB, historian, event log, recipe book and stats collector. cfg.TagMeta seeds each tag's engineering range and its alarm limits (Hi / HiHi).
scada.BindScreen(services, form, opt) Walks the form once and auto-binds: every TagName() widget to its tag, the AlarmPanel to the live AlarmDB, the TrendPanel to TrendTag's live + historical feed, the StatsPanel to StatsTags.
services.Start() Turns the runtime on: alarm bridge (alarm → event + notification), a per-tag limit watch, historian recording and stat folding.
driver.NewPoller(...).Start() Reads the two sim waveform points into services.Tags every 500ms — the stand-in for a Modbus / S7 field device.

Tags

Tag Range Alarm limits Sim waveform
level 0–100 % Hi 80, HiHi 95 sine:min=0,max=100,period=20s
temp 0–120 ℃ Hi 90 sine:min=20,max=110,period=30s

Both TagPoints set Type: driver.TypeFloat64. This is required: the zero-value DataType is TypeBool, which would coerce the sine floats to booleans.

Screen

  • Tank — bound to level by its design-time tag name.
  • DigitalDisplay (7-segment) — bound to temp; segments recolor at/above Hi. (Gauge is not used for the tag binding because it has no SetTagName seam — only the eight industrial widgets do; BindScreen binds through that seam.)
  • AlarmPanel — live view of the AlarmDB; level trips Hi/HiHi and temp trips Hi each cycle, so rows appear and clear on their own. Click a row's ACK to acknowledge.
  • TrendPanel — its owned LineChart scrolls temp live; the range buttons replay temp's persisted history from the historian.
  • StatsPanel — running count / min / max / avg / last for level and temp; click 清零 to reset a tag.

Run

# needs a desktop session — Cairo + GLFW, cannot run headless
go run ./examples/hmi

# or build a binary
CGO_CFLAGS="$(pkg-config --cflags cairo)" go build -o hmi ./examples/hmi/

The historian, event-log and recipe stores are created under os.UserConfigDir()/silk-hmi (falling back to the OS temp dir).

Watch it: the temperature readout eases toward each new sample, the trend line scrolls, the statistics table folds every poll, and alarm rows raise and clear as level and temp cross their limits — all driven by the simulator through the shared Services, with the screen wired by a single BindScreen call.

Documentation

Overview

Silk 组态 / HMI — end-to-end example on the scada.Services runtime.

Proves the WHOLE headless runtime loop wires up to a live screen the way the ged code generator now emits it: a hardware-free simulator feeds the shared real-time tag registry, and a single scada.BindScreen call walks the form and auto-binds every industrial widget + operator panel to the backend — this file writes ZERO per-widget gui.BindTag glue of its own.

sim.Sim (sine waveforms)
  -> driver.Poller               reads every 500ms
      -> services.Tags           core.TagDB — the one real-time point registry
          ├─ AlarmDB.Watch       -> alarm bridge -> event log + notify + AlarmPanel
          ├─ Historian.Record    -> SQLite sample store (TrendPanel range replay)
          ├─ Stats.Collector     -> StatsPanel (count / min / max / avg / last)
          └─ BindScreen tag bind:
                 Tank.SetTagName("level")           -> BindTagAnimated -> fill eases
                 DigitalDisplay.SetTagName("temp")  -> BindTagAnimated -> readout eases
              TrendPanel (TrendTag "temp")          -> owned LineChart scrolls live

Everything below the tag registry is installed by services.Start() and scada.BindScreen(); the sim.Sim + driver.Poller stand in for a field device.

Run (needs a desktop — Cairo + GLFW, cannot run headless):

go run ./examples/hmi

Jump to

Keyboard shortcuts

? : This menu
/ : Search site
f or F : Jump to