Package s7comm decodes classic S7Comm PDUs — the Siemens S7- 300 / S7-400 / S7-1200 / S7-1500 PLC protocol that rides on ISO-on-TCP (RFC 1006, default TCP port 102). S7Comm is the dominant factory-floor PLC protocol in European and Asian manufacturing — and the canonical Stuxnet target — used by Siemens TIA Portal, libnodave, snap7, and a long tail of HMI/ SCADA stacks talking to S7 PLCs.
Operationally, S7Comm carries:
- **Variable Read/Write** — by far the most common traffic; HMIs and supervisory layers pull live I/O, DB, M, T, C values out of the PLC and write setpoints back.
- **Setup Communication** — the three-way negotiation (CR/CC COTP handshake + Setup Communication PDU) that opens a session and exchanges PDU-Length / Max-Calling-AMQP.
- **PLC Control** — Run/Stop/Resume/MemoryReset and block upload/download (firmware programming) — the dangerous functions a pentester / red-teamer targets.
- **Userdata** (ROSCTR 0x07) — diagnostics, time-of-day get/ set, security, alarms; a richer per-subfunction tree the decoder surfaces as raw `parameters_hex` for downstream walkers.
Wrap-vs-native judgement
Native. The wire format is fully reverse-engineered and stable (libnodave, snap7, Wireshark s7comm dissector). The transport stack is tight: 4-byte TPKT header (RFC 2126) + variable-length COTP header (ISO 8073 §13.4) + 10-or-12- byte S7 header + parameter block + data block. No crypto at the parse layer for classic S7Comm; the newer S7Comm- Plus (S7-1500) uses an integrity-protected variant which is out of scope for this decoder.
What this package covers
byte 0: Version (= 3 for S7Comm).
byte 1: Reserved (= 0).
bytes 2-3: Length (uint16 BE; total bytes of the TPKT packet including this 4-byte header).
**COTP header** (ISO 8073 §13.4, variable length; minimum 3 bytes for the common DT data PDU):
byte 0: Length Indicator (LI; count of header bytes EXCLUDING the LI byte itself — so total COTP header = LI + 1).
byte 1: PDU Type (high nibble; classic values are 0xE CR / 0xD CC / 0x8 DR / 0xC DC / 0xF0 DT / 0x7 ED / 0x2 EA / 0x6 RJ / 0x1 ER).
bytes 2+: PDU-type-specific. For the DT (data) PDU that carries every S7Comm PDU, byte 2 contains the TPDU Number (bit 7 EOT — end-of-TSDU; bits 0-6 = TPDU number).
**9-entry COTP PDU type name table**: 0xE0 CR (Connection Request) / 0xD0 CC (Connection Confirm) / 0xF0 DT (Data) / 0x80 DR (Disconnect Request) / 0xC0 DC (Disconnect Confirm) / 0x70 ED (Expedited Data) / 0x20 EA (Expedited Ack) / 0x60 RJ (Reject) / 0x10 ER (TPDU Error).
**S7 header** (10 or 12 bytes; big-endian):
byte 0: Protocol ID (= 0x32).
byte 1: ROSCTR (Remote Operating Service Control).
bytes 2-3: Reserved (= 0x0000).
bytes 4-5: PDU Reference (uint16 BE; correlation ID pairing request and response).
bytes 6-7: Parameter Length (uint16 BE).
bytes 8-9: Data Length (uint16 BE).
bytes 10-11 (ROSCTR 0x02 / 0x03 only): Error Class + Error Code. The decoder surfaces both as integers and decodes the Error Class against the documented name table.
**4-entry ROSCTR name table** (S7Comm wiki / Wireshark): 0x01 `Job_Request` (request) / 0x02 `Ack` (acknowledge without data) / 0x03 `Ack_Data` (acknowledge with response data) / 0x07 `Userdata` (diagnostics + time + security + alarms — richer subfunction tree surfaced as raw `parameters_hex`).
**First-byte function code from the parameter block** (per-Job_Request / Ack_Data only, since Userdata uses a different per-subfunction header):
**15-entry function code name table**: 0x00 `CPU_services` / 0x04 `Read_Var` / 0x05 `Write_Var` / 0x1A `Request_Download` / 0x1B `Download_Block` / 0x1C `Download_Ended` / 0x1D `Start_Upload` / 0x1E `Upload` / 0x1F `End_Upload` / 0x28 `PLC_Control` / 0x29 `PLC_Stop` / 0xF0 `Setup_Communication`.
**9-entry Error Class name table** (ROSCTR 0x02 / 0x03 only): 0x00 `No_Error` / 0x81 `Application_Relationship` / 0x82 `Object_Definition` / 0x83 `No_Resources_Available` / 0x84 `Error_On_Service_Processing` / 0x85 `Error_On_Supplies` / 0x87 `Access_Error`.
**Parameter + data block surfacing** — the per-function parameter shape (Read_Var carries a count of Items followed by per-Item ItemSpec records with Variable Specification + length + DB number + Address; Write_Var adds a data block with Data Item records) is dataset- specific and surfaced as `parameters_hex` and `data_hex` for downstream per-function walkers.
What this package does NOT cover (deliberately out of scope)
- **Network framing** — feed S7Comm bytes after the TCP- segment-header strip (default TCP port 102 with one TPKT-encapsulated COTP-encapsulated S7 PDU per TCP segment in the well-behaved case; TPKT can span segments in pathological cases that this decoder does not reassemble).
- **COTP CR / CC parameter walker** — the Connection Request / Confirm PDUs carry parameter blocks (Calling/Called TSAP, TPDU size) that influence the S7Comm session parameters; the decoder identifies the PDU type via the name table but does not parse the parameter blocks (out of scope unless we need the TSAP for risk gating).
- **Per-function parameter walkers** — Read_Var ItemSpec records (Variable Specification + Transport Size + Length
- DB number + Area + Address bit string), Write_Var Data Item records, PLC_Control filename strings, Setup_Communication PDU-Length negotiation — all surfaced as `parameters_hex` for future per-function decoders.
- **Userdata subfunction tree** — ROSCTR 0x07 carries an additional parameter sub-block with a function group (Programmer Commands / Cyclic Services / Block Functions / CPU Functions / Security Functions / Time Functions / NC Programming) and subfunction code (e.g. 0x01 Read SZL, 0x02 Read Diagnostic List, 0x82 Set Clock). All surfaced as `parameters_hex` and `data_hex`.
- **S7Comm-Plus** — the integrity-protected wire format used by S7-1500 (and optionally S7-1200 v4+) is a separate decoder; protocol ID is 0x72 not 0x32. This package specifically targets classic S7Comm (0x32).
- **State-machine reasoning** — session setup, PDU-Length negotiation, upload/download multi-PDU sequencing; higher- level analysis.
Index ¶
Constants ¶
This section is empty.
Variables ¶
This section is empty.
Functions ¶
This section is empty.
Types ¶
type Result ¶
type Result struct {
TotalBytes int `json:"total_bytes"`
// TPKT (RFC 2126)
TPKTVersion int `json:"tpkt_version"`
TPKTLength int `json:"tpkt_length"`
// COTP (ISO 8073)
COTPLengthIndicator int `json:"cotp_length_indicator"`
COTPPDUType int `json:"cotp_pdu_type"`
COTPPDUTypeName string `json:"cotp_pdu_type_name"`
COTPTPDUNumber int `json:"cotp_tpdu_number,omitempty"`
COTPEndOfTSDU bool `json:"cotp_end_of_tsdu,omitempty"`
// S7 header
S7ProtocolID int `json:"s7_protocol_id,omitempty"`
ROSCTR int `json:"rosctr,omitempty"`
ROSCTRName string `json:"rosctr_name,omitempty"`
PDUReference int `json:"pdu_reference,omitempty"`
ParameterLength int `json:"parameter_length,omitempty"`
DataLength int `json:"data_length,omitempty"`
// Ack / Ack_Data only
ErrorClass int `json:"error_class,omitempty"`
ErrorClassName string `json:"error_class_name,omitempty"`
ErrorCode int `json:"error_code,omitempty"`
// Function code (first byte of parameter block; Job_Request +
// Ack_Data only).
FunctionCode int `json:"function_code,omitempty"`
FunctionName string `json:"function_name,omitempty"`
// Opaque payload bytes (surfaced for downstream walkers).
ParametersHex string `json:"parameters_hex,omitempty"`
DataHex string `json:"data_hex,omitempty"`
}
Result is the structured decode of an S7Comm PDU (TPKT + COTP + S7 header + opaque parameter + data).